Semiconductor Protection Fuses

Medium voltage High voltage Low voltage Low voltage

Air and oil insulated switch gear (HHB)

Air and gas insulated switch gear (HHF)

Capacitor protection (HHC)

Transformers under oil (HHO)

Overhead lines (HHP)

High voltage fuse (HHD)

Capacitor protection (HHD)

Motor (HHM)

Distribution transformers

Voltage transformers

(PT)

D fuses: AC 400 V - AC 500 V / DC 250 V - DC 500 V Current rating: 0.5 A to 200 A

Knife blade fuses (NH)

Miniature fuses (G):

Surface mount & thru hole for PC boards

SMD 125V & 250V

Cylindrical sizes:

5 x 20 - 6.3 x 32 - 5 x 25

5 x 30 - 8 x 50 - 8 x 85

10 x 85 - 8 x 120 - 8 x 150 mm


Hill Technical Sales specializes in providing innovative fuse protection for: Fuses for semiconductor protection offer high current interrupt capabilities for short circuit faults with lower values of I2T and power losses. Fuses are IEC and UL recognized. Our fuses for medium voltage capacitors and capacitor banks have high interrupt rating of 63kA and can be directly mounted to capacitor bushing with: threaded holes on both ends, a threaded hole and L-bracket or L-brackets on both sides. Specials mounting for your unique requirements are available. We also have fuses for medium and high voltage applications like; switch gear, motor protection, transformers including submersibles and cable feeders. Other lines of fuses include, miniature electronic fuses, bottle fuses, DIAZED, NEOZED, and cylindrical type. Some of our fuse products have been designed for specific use or applications such as traction, rectifiers, inverters, converters, mining, drives, UPS, Forklift, and marine.

Semiconductor Fuses

Class Voltage Rating Current Rating Standards Product Reference
aR 660 to 1000VAC 10 to 400A DIN 43653; IEC 60269-4; DIN VDE 0636-40; UL 248-13
gR/aR 440 to 500VAC 2 to 200A DIN VDE 0636-40; DIN 49515/49360
gR/aR 660 to 5000VDC 6 to 800A IEC 60269-4; DIN VDE 0636-40;DIN 49515/49360
aR 240 to 700VAC 5 to 900A IEC 60269-4; BS 88-4
aR/gR 500 to 200VAC 16 to 800A DIN 43620; DIN 43653
aR * 700AC / 1300VAC 50 to 1600A DIN 43653; DIN VDE 0636-40;IEC 60269-4;UL 248-13
* UL Recognition
Class Size

Type

Voltage rating

Current Rating

Standard

Product Reference
gRL 00/1/2/3 Knife blade contact fuses 690VAC 16 to 800A DIN 43620 URL
Fuses with bolted contact 690VAC 16 to 800A DIN43653
Cylindrical fuses 500 to 690VAC 6 to 100A N/A
Class

Size

Type

Voltage rating

Product Reference
gR/aR/gRL 5 x 20 mm Cylindrical fuse AC 250 V URZ
6.35 x 32 mm AC 500 - 1000 V
10 x 38 mm AC 600 - 1000 V
14 x 51 mm AC 500/600V - 690/700 V
22 x 58 mm AC 500/600 V - 690/700 V
27 x 60 mm AC 660 V - 1000 V
Standards: IEC 60269-4 and -1; DIN VDE 0636-23;UL 248-13

Fuses For Semiconductor Protection

North American and European Standard TYPE SQB Sizes 1, 2, 3 AND 4
semiconductor fuse
f longblade Long blade version
Square body semiconductor fuse type, SQB are available in4 different body sizes. Each size is available in various mounting styles, body sizes, and amp ratings to allow the greatest flexibility in equipment design. SQB fuses provide superior performance for the protection of today's power semiconductors. The use of silicated sand as the quenching medium together with special shape and form of the pure silver melting elements gives excellent results of low I2t current interrupting ratings. The elements are welded to the contacts and provide extended life under high cycling load conditions. Fuses are available to be fitted with micro switches.
  • High interrupting rating 200 kA
  • Very low I2t -values
  • Voltage ratings AC 690/700 V and AC 1250/1300 V
  • Suitable for North American and European standard
  • Reliable also at high cyclic loading
  • Fuse bases and other accessories for Fuse semiconductor protection are available
Class Size

Voltage rating

Current Rating

Standard

Product Reference
aR 1/2/3/4 AC 700 V / AC 1300 V 50 up to 3000 A DIN 43653 URS
DIN VDE 0636-40
IEC 60269-4
UL 248-13
 
Download PDF Catalog for more Information
 

Fuses For Semiconductor Protection European Standard Class gRL (gs)

f 007
f 011 Side and end view
This is the first full range of class gs fuse now recognized by the IEC as class (gs). gRL class (IEC class gs) fuses offers superior performance by combing of two fuse classes into one. Type gRL fuses provide protection to power electronic equipment and cables with low power losses and low I2t-values simultaneously. Fuse type gRL offers: Semiconductor protection against short circuit faults via their Ultra Rapid "gR" characteristic(semiconductor fuse). Cable protection against overload via their "gL" characteristic.
  • High current limitation
  • Low power losses
  • Semiconductor protection against short circuit faults
  • Cable protection against overload current
  • Low I2t -values
  • High interrupting rating up to 200 kA
  • Compliance with the following standards: IEC 60269-1 / -2-1 and -4 DIN
  • Class gRL follows the requirements of the new standardized class gS
  • Fuse bases and other accessories for Fuse semiconductor protection are available
 
Download PDF Catalog for more Information
 

Fuses For Semiconductor Protection Cylindrical Fuses - European Standard

f 013c
siba fuse base 10x38 Isolated fuse base for fuses with cylindrical contact caps shown below
Cylindrical ultra-rapid semiconductor fuses are available in 6 different sizes. They are available without or with or built-in striker pin for fuse blown indication or operation of micro-switches.
  • High interrupting rating up to 300 kA
  • Voltage rating 250 up to 1000 V AC
  • Protection of Power Semiconductors according to IEC 60269-1 and -4
  • With or without integrated striker pin
  • Class aR according to IEC 60269-4 and DIN VDE 0636-40
  • Class gR according DIN VDE 0636-40
  • Fuse-Bases / Fuse-Clips and Accessories are available
Class Size

Voltage rating

Current Rating

Standard

Product Reference
gR aR gRL 5 x 20 mm AC 250 V 125 mA - 200 A IEC 60269-1 and -4DIN VDE 0636-23UL 248-13 URZ
6.35 x 32 mm AC 500 - 1000 V
10 x 38 mm AC 600 - 1000 V
14 x 51 mm AC 500/600V - 690/700 V
22 x 58 mm AC 500/600 V - 690/700 V
27 x 60 mm AC 660 V - 1000 V
 
Download PDF Catalog for more Information
 

DC-Application / Traction Fuse

f 017
f 021 5000 VDC fuse
DC Fuses are offered in clip-mounted and bolt-design. The fuses are used for applications in traction-, battery, and railway main- circuits. DC fuses are largely used for the protection of frequency-inverters. Because the application it is possible in a big variety you should contact Hill Technical to have information regarding the use at different voltage ratings, classes or L/R's.
  • Designed for heavy duty applications
  • Shock and vibration proved
  • Some types with additional microswitches
  • Developed according customers specification
  • Individual tested time constants
  • Designed for long lasting live under severe service conditions
  • OEM inquires for custom Traction Fuse are welcome
Class

Voltage rating

Current Rating

Standard

Product Reference
gR aR gRL DC 660 V - DC 5000 V 6 A - 800 A UIC 550 IEC 60269-4 DIN VDE 0636-23   URDC
 
Download PDF Catalog for more Information
 

Miniature Fuses G

siba fuses g
siba fuses g50 Fuse holder for 5 x 20 mm fuse
  • Very high interrupting rating up to 70 kA
  • High ratings of voltages up to 10 kV
  • Large range of current ratings available for semiconductor protection
  • Fuse bases, clips and accessories are available
Class Size

Voltage rating

Current Rating

Standard

Product Reference
F fast acting T time lag TT very slow M medium time lag FF very fast acting

Cylindrical fuses:

5 x 20 6.3 x 32 5 x 25 5 x 30 8 x 50 8 x 85 10 x 85 8 x 120 8 x 150 mm
65 V - 10kV 6 A - 800 A IEC 60127 DIN VDE 0820 CEE4 UL 248-14, UL 512 CSA-C22.2 No. 248.14 G
Radial lead 2 pin fuses: KS, Ø 8.4 mm 250 V 40mA - 10A
SMD fuses: Voltage ratings: 65 V - 10 kV 125-250 V 40mA - 15A
 
Download PDF Catalog for more Information
 

Medium Voltage Fuses For Capacitors

siba fuses hhc
f 030 Dual UNC thread drawing
f 033 UNC and bracket connected drawing
Capacitor protection fuses can easily be fitted directly onto capacitor bushings, because they can be fitted with threaded holes at either ends, or threaded one end and with bracket on the other end. Their electrical characteristic being current limiting back up suits the protection requirements of capacitors. Characteristic following capacitor protection needs for back up protection. Cartridge type current limiting Special mounting brackets available on request.

Voltage rating

Current Rating

Standard

Product Reference
3.2/ 4.8 / 5.5 / 7.2 / 8.3 / 15.5 / 23kV 6.3 - 500 A IEC 60 282-1 IEC 60 549 HHC
 
Download PDF Catalog for more Information
 

High Voltage Fuses

f 035
German DIN standard for air and gas insulated switchgear and outdoor switchgear. High voltage Fuse-links have parallel connected pure silver fuse-elements. The design and methods of production of the elements ensures narrow tolerances of the time-current characteristics. The fuse elements are wound on a ceramic support and are attached to the silver plated connection caps by means of spot-welding.
f 037

The connection caps are fitted inside the silver plated copper end caps by spot welding. The copper end caps themselves are press-fitted onto the porcelain tube, which is glazed inside and outside. The end caps are furthermore mechanically fixed to the porcelain tube and additionally sealed by a durable elastimer sealing medium. This sealing method has been proven over many decades of positive field experience and ensures tightness against ingress of humidity. Inquires for fuse high voltage custom applications are welcome.

 
Download PDF Catalog for more Information
 

High Voltage Fuses

f 039
f 042 Top view
Motor Circuit Protection - Din And British StandardMotor Rated Fuses are available in German DIN Standard and British Standard Design. The large variety in body sizes / mounting style/ Voltage and Amp rating allow great flexibility for the designer of switchboard panels.
  • Protection of Motor circuits according IEC 60644. High resistance against cyclic and peak current loads, avoiding ageing because of high motor start up currents
  • Low power losses, minimizing temperature increase in narrow contactor enclosures
  • Low minimum interrupting currents for operation of over-currents in the range 3 - 3.5 x rated current
  • Availability of temperature limiters for switchgear protection against excessive temperature rise
  • Type tested according IEC 60470 in cooperation with the major European Panel builders
  • Available in DIN 43625 and BS 2692 dimensions
Class

Voltage rating

Current Rating

Standards

Product Reference
Back up AC 3.6 - 7.2 kV 50 - 450 A Dimensions: DIN 43625 and BS 2692Electrical: IEC 60644 IEC 60470 IEC 60282-1 BS 2692 HHM
 
Download PDF Catalog for more Information
 

Medium Voltage Fuses

f 044
f 047 Side view
European Standard For Installation Inside Transformers Under Oil. These are general-purpose fuses for installation in transformers; they offer space and cost saving in distribution transformer substation design. They are designed to protection against short-circuit and internal transformer faults and also offer bursting protection of the transformer through specific characteristic of the fuse-link resistance against ageing  
Download PDF Catalog for more Information
 

Medium Voltage Fuses - British Standard

f 049
f 052 Side view
Medium voltage fuses according British Standard are backup fuses for the protection of substations up to 24 kV. The fuse links of this section comply with the following national and international standards:
  • IEC 60282-1
  • BS 2692
  • ESI 12-8
Design and construction of these fuses follow the well-proven concept of all high-voltage fuse-links. Pressure resistant encapsulation and a high-grade ceramic is used. Contact material consists of silver plated high conductivity copper. The pure silver melting elements are provided with appropriate notches to ensure small time/current-curve tolerances and low let-through currents. The arc quenching quartz sand is subject to special survey criteria regarding its composition, grain size and humidity content.  
Download PDF Catalog for more Information
 

Medium Voltage Fuses - French Standard

f 054
f 057 Side view
For Air & Gas Insulated Switchgears Outdoor Switchgears High-Voltage fuse-links of size 55 x 520 mm are suitable for the protection of power transformers used in energy distribution. Usually they are used for indoor application, outdoor use is possible. In case of a short circuit the fuse will interrupt fault currents between five times the fuse rated current and the rated breaking current. Standards:
  • IEC 60282-1
  • NFC 64210
 
Download PDF Catalog for more Information
 

Medium Voltage Fuses - European Standard

f 059
f 062
Medium voltage fuses Plug-in fuses for overhead lines Medium voltage fuse links including overhead line connectors are provided as a set. They allow in overhead lines to provide fuse protection on pole mounted distribution transformers. The set consists of a high voltage fuse link including a set of connectors.  
Download PDF Catalog for more Information
 

Low Voltage Fuses - European NH Knife-Blade Fuse System

f 064
f 067 Side and end view
Description: European NH Knife-Blade Fuse System SIBA NH Fuse-links with top and center indicator are available in a large variety of voltage ratings, body sizes and operating classes: Sizes: 000, 00, 0, 1, 2, 3, 4a and 4 Voltage ratings: AC 400 / 500 / 690 / 1000 / 1500 V Fuse bases and accessories available, made of sheet steel base plate with ceramic support Low power losses and temperatures All fuse links are corrosion resistant

Operation class

Application

gG General Purpose Cable and Line protection
gB For general application
aM Motor circuit short circuit protection
gTr General Purpose Transformer Protection
gTF For general application
Standards: IEC 60269-1-2 / EN 60269-1-2 DIN VDE 0636 part 201 DIN VDE 0636 part 2011 DIN 43620 Approvals: Germany, Austria, Switzerland Combination indicator (top and center) for easy identification of blown fuses High interrupting rating up to 120 kA Voltage ratings AC 400 - 1500 V Operation classes gG, gB, aM, gTr, and gTF available for all applications Removal tags: Standard design in metal, insulated removal tags available.  
Download PDF Catalog for more Information
 

Fuses For Semiconductor Protection - European Standard

f 069
f 072 Top, end and side view
They are designed to protect power semiconductors according to IEC 60269-1 IEC 60269-4 and comply with DIN 43653. Fuses are available without or with top indicator or with microswitch. aR class 10 A - 400 A according to IEC 60269-4 and DIN VDE 0636-40. Fuse bases and accessories are also available. Sizes 000 And 00 Class: aR Voltage rating: AC 660 V - AC 1000 V and 750VDC (when used as a DC fuse) Current rating: 10 A to 400 A Standards: DIN 43653, IEC 60269-1 IEC 60269-4, DIN VDE 0636-40 and UL 248-13 These fuses have extremely high interrupting rating 100 kA - 300 kA with voltage ratings AC 660 V - AC 1000 V  
Download PDF Catalog for more Information
 

Fuses For Semiconductor Protection - European Standard

f 074
f 077 Type DV
TYPE D0 fuse / D fuse D Fuses, also known as type Diazed/ Neozed fuses are supplied in the following sizes, ND, DII, DIII, DVI, DV, D01, D02, and D03. All fuses have color-coded blown fuse indicators. Voltage rating: AC 440 V - AC 500 V Current rating: 2 A to 200 A Class: gR / aR / aRL Standards: IEC 60269-4, DIN VDE 0636-40 DIN 49515 / 49360 Class gR for rated currents up to 100 A Class aR for rated currents above 100 A All fuses have blown fuse indicators Protection of Power Semiconductors according to IEC 60269-4 Fuse Bases and Accessories are available  
Download PDF Catalog for more Information
 

Knife Blade Contact Fuse - German Standard

f 079
f 082 Side and end view
Ultra rapid knife blade fuse contact fuses type NH style are available in many different sizes and four voltage ratings. They follow DIN/VDE -IEC standard and can be fitted in open fuse bases. Usage in fuse bases or switches requires the comparison of the power loss of the fuse with the power acceptance of the base or switch. All type NH-fuses are available with either integral blown fuse indicator or a separately fitted trip indicator fuse for microswitch operation. Class: aR/gR Sizes: 000 / 00 / 0 / 1 / 2 and 3 Voltage ratings: AC 500 V - 2000 V Current ratings: 16 A up to 800 A High interrupting rating up to 120 kA Voltage rating AC 500 V - AC 2000 V Compliance with DIN 43620 and DIN 43653 standard Fuses with blown fuse combination indicator Class aR according to IEC 60269-4 and DIN VDE 0636-40 and Class gR according to DIN VDE 0636-40 Fuse bases / Switches and Accessories are available  
Download PDF Catalog for more Information
 

Fuses For Semiconductor Protection - European-British Standard

f 084
f 087 Size 8.4 x 38 m
Protection of Power Semiconductors according to IEC 60269-4 Complies with BS 88 Standard and are available with or without striker for microswitch operation, Class aR 5 A - 900 A according to IEC 60269-4 Standards: IEC 60 269-4, BS 88-4 Class: aR Voltage ratings: AC 240 V - AC 700 V Current ratings: 5 A - 900 A High interrupting rating 100 kA Voltage rating AC 240 V - AC 700 V  
Download PDF Catalog for more Information
 

D Fuses

f089
f 092 Type D II
The diameter of the bottom of the fuse-links are graduated according to current rating. A gauge piece that is matched to the fuses current rating is mounted in the fuse base. This prevents them from being interchangeable. Voltage rating: AC 400 V - AC 500 V / DC 250 V - DC 500 V Current rating: 0.5 A to 200 A Class: gG/gL Standards: IEC 60 269-3-1, DIN VDE 0636 Part 301, DIN 49515 / 49360 / 49365 / 49522 Systems: ND - AC 500 V - DIN 49360 D - AC 500 V - DIN 49515 / DO - AC 400 V - DIN 49522  
Download PDF Catalog for more Information
 

Class

Voltage rating

Current Rating

Standards

Product Reference

aR 660 to 1000VAC 10 to 400A DIN 43653; IEC 60269-4; DIN VDE 0636-40; UL 248-13 URB
gR/aR 440 to 500VAC 2 to 200A DIN VDE 0636-40; DIN 49515 / 49360 URD
gR/aR 660 to 5000VDC 6 to 800A IEC 60269-4;DIN VDE 0636-40;DIN 49515/49360 URDC
aR 240 to 700VAC 5 to 900A IEC 60269-4; BS 88-4 URE
aR/gR 500 to 200VAC 16 to 800A DIN 43620; DIN 43653 URM
aR * 700AC / 1300VAC 50 to 1600A DIN 43653; DIN VDE 0636-40;IEC 60269-4;UL 248-13 URS
* UL Recognition Class gRL, Size: 00 / 1 / 2 / 3 Product Reference: URL

Type

Voltage rating

Current Rating

Standard

Knife blade contact fuses 690VAC 16 to 800A DIN 43620
Fuses with bolted contact 690VAC 16 to 800A DIN43653
Cylindrical fuses 500 to 690VAC 6 to 100A N/A
Class gR/aR/gRL Size: Cylindrical fuse Product Reference: URZ

Size

Voltage rating

5 x 20 mm  AC 250 V
6.35 x 32 mm AC 500 - 1000 V
10 x 38 mm AC 600 - 1000 V
14 x 51 mm AC 500/600V - 690/700 V
22 x 58 mm AC 500/600 V - 690/700 V
27 x 60 mm AC 660 V - 1000 V
Standards: IEC 60269-4 and -1; DIN VDE 0636-23;UL 248-13